| Only a combination of accelerated
test determines the performance of the coating system at practical exposure
conditions.
Marine
by ASTM B-117: This
salt spray test shows no defects after 10,000 hours - reflecting ten years
extension of life time in real life at the sea side.
Urban by ASTM B-278: City life causes acid
rain, FIN GUARD Silver shows no defects after 3,000 hours reflecting nine
years of exposure to an urban climate.
Industrial by DIN 50018 or Kesternich test:
Hundred and twenty cycles equivalent to ten years of heavy polluted sulphuric
air have been proven success of FIN GUARD Silver.
Tropical area by Ozone exposure - temperature changes-
humidity: FIN GUARD Silver was exposed in a humid cabinet to
Ozone and extreme temperature fluctuations. By succeeding FIN GUARD Silver
proves to be able to cope with tropical weather conditions.
Dust and dirt by DIN 40046: Very limited
dust adhesion was found compared to regular aluminum surfaces.
|